Advanced Error Check Feature Advanced Error Check Feature. This feature creates a centralized list of Error Messages and Warning Messages compiled from decades of technical support and model troubleshooting experience, reporting both critical errors and settings changes (warnings) that may not be immediately apparent when the model is analyzed. This list can be generated before an Analysis has been run, placing the user just one click away from the List of Errors/Warnings before conductiong the analysis. See more here ( Advanced Error Check ).
Advanced Error Check Feature. This feature creates a centralized list of Error Messages and Warning Messages compiled from decades of technical support and model troubleshooting experience, reporting both critical errors and settings changes (warnings) that may not be immediately apparent when the model is analyzed. This list can be generated before an Analysis has been run, placing the user just one click away from the List of Errors/Warnings before conductiong the analysis. See more here ( Advanced Error Check ).
Animated Map Over Time Create an AVI or Bitmap animation. The animation may be used with contours and pipe emphasis enabled. More
Create an AVI or Bitmap animation. The animation may be used with contours and pipe emphasis enabled. More
Animated Pipe Profiling Create animated or simple pipe profiles for pipelines or a path through a looped system. Specify the first and last nodes and the rest are done automatically. The HGL envelope and results may be displayed. More
Create animated or simple pipe profiles for pipelines or a path through a looped system. Specify the first and last nodes and the rest are done automatically. The HGL envelope and results may be displayed. More
Automatic Junction Node Layout Automatically insert junction nodes at specified intervals in long pipelines.
Automatic Junction Node Layout
Automatically insert junction nodes at specified intervals in long pipelines.
Autosave Feature AutoSave is automatically enabled when creating new files, but may be turned off by the user. The time interval for autosaving may be set by the user, but defaults to 10 minutes. Autosaved copies are not automatically implemented; load any autosaved copy from the Autosave Menu, then save it manually, and it will become the working copy. The user is prompted before autosaving, and an option exists to accept or skip the autosave.
AutoSave is automatically enabled when creating new files, but may be turned off by the user. The time interval for autosaving may be set by the user, but defaults to 10 minutes. Autosaved copies are not automatically implemented; load any autosaved copy from the Autosave Menu, then save it manually, and it will become the working copy. The user is prompted before autosaving, and an option exists to accept or skip the autosave.
Background Images Display image files in the background including DXF, Shape, TIF and JPG. More
Display image files in the background including DXF, Shape, TIF and JPG. More
Built-in Valve Characteristics A number of built-in standard valves characteristics are provided, e.g., gate, globe, butterfly, and many more valves are included.
Built-in Valve Characteristics
A number of built-in standard valves characteristics are provided, e.g., gate, globe, butterfly, and many more valves are included.
CAD, EPANET, Google Earth, Microsoft Excel Spreadsheet & GIS Import & Export AutoCAD: The DXF Exchange feature allows users to import and export piping data (lines and polylines) from AutoCAD to create a pipe system. ArcGIS: The GIS Exchange feature imports and exports model data to and from ArcGIS Shapefiles. Google Earth files can be exported, and imported with or without embedded KML attributes. EPANET: .INP files can be imported and exported. Microsoft: Models can be built from Microsoft Excel spreadsheets, which is useful for long pipelines/transmission mains. AutoCAD, ArcGIS and Google Earth Import and Export are Pro Package features. More
CAD, EPANET, Google Earth, Microsoft Excel Spreadsheet & GIS Import & Export
AutoCAD: The DXF Exchange feature allows users to import and export piping data (lines and polylines) from AutoCAD to create a pipe system. ArcGIS: The GIS Exchange feature imports and exports model data to and from ArcGIS Shapefiles. Google Earth files can be exported, and imported with or without embedded KML attributes. EPANET: .INP files can be imported and exported. Microsoft: Models can be built from Microsoft Excel spreadsheets, which is useful for long pipelines/transmission mains. AutoCAD, ArcGIS and Google Earth Import and Export are Pro Package features. More
AutoCAD: The DXF Exchange feature allows users to import and export piping data (lines and polylines) from AutoCAD to create a pipe system.
ArcGIS: The GIS Exchange feature imports and exports model data to and from ArcGIS Shapefiles.
Google Earth files can be exported, and imported with or without embedded KML attributes.
EPANET: .INP files can be imported and exported.
Microsoft: Models can be built from Microsoft Excel spreadsheets, which is useful for long pipelines/transmission mains.
Check Valve Animation Visually Represents Check Valve Position at All Simulation Times. (KYnetic only). More
Visually Represents Check Valve Position at All Simulation Times. (KYnetic only). More
Connect Crisscross Pipes Connects disconnected pipes. If pipes cross but are not connected, this feature will add a junction node at the connection point (KYnetic only). Improved for 2026, now end nodes that are disconnected from pipes can be automatically snapped to the nearest pipe. Formerly, only hydrants, meters and on/off valves could be snapped to the nearest pipe. More
Connects disconnected pipes. If pipes cross but are not connected, this feature will add a junction node at the connection point (KYnetic only). Improved for 2026, now end nodes that are disconnected from pipes can be automatically snapped to the nearest pipe. Formerly, only hydrants, meters and on/off valves could be snapped to the nearest pipe. More
Contouring & Emphasis Generate, display, and print contour maps for a variety of node data and results (e.g., elevation, pressure). More
Generate, display, and print contour maps for a variety of node data and results (e.g., elevation, pressure). More
Demand Import from Excel by Address or Lat/Long Import demands to junction nodes or as residential meters on pipes using an Excel spreadsheet to match junctions/pipes within the model to addresses or latitude/longitude values in the spreadsheet. More
Demand Import from Excel by Address or Lat/Long
Import demands to junction nodes or as residential meters on pipes using an Excel spreadsheet to match junctions/pipes within the model to addresses or latitude/longitude values in the spreadsheet. More
Design Criteria Feature This feature allows users to input an allowable node pressure range (e.g., 30 psi to 100 psi for a municipal system), and the software determines the difference between the pressure at any given node and the upper and lower ends of the range. Specifically, the Design Point is defined as the percent difference between the user-defined upper/lower pressure limit for each node (which are set using either the Global Values or Local Values) and the pressure value calculated for that node by the model during analysis. So, for example, if the Design Point = 75.5%, then the calculated pressure is 75.5% of the way to the Design Point. The formula for calculating the design point is 100% * (Value – Min Value)/(Max Value – Min Value). More
This feature allows users to input an allowable node pressure range (e.g., 30 psi to 100 psi for a municipal system), and the software determines the difference between the pressure at any given node and the upper and lower ends of the range. Specifically, the Design Point is defined as the percent difference between the user-defined upper/lower pressure limit for each node (which are set using either the Global Values or Local Values) and the pressure value calculated for that node by the model during analysis. So, for example, if the Design Point = 75.5%, then the calculated pressure is 75.5% of the way to the Design Point. The formula for calculating the design point is 100% * (Value – Min Value)/(Max Value – Min Value). More
Device Parameter Range Analysis Varies a parameter value within a specified range to see the effect on the system. The parameter is associated with a double-sided node such as a pump or valve. The user selects a parameter within the node input data, then defines an allowable range. The program will run multiple analyses simultaneously to output the variation in the remainder of system based on iterative values within the allowable range. For instance, vary the flow coefficient of a valve to see the effect on the system pressures and flows. This is a KYPipe-only feature, available within the KYnetic Interface and the KYnetic Ribbon Interface. More
Device Parameter Range Analysis
Varies a parameter value within a specified range to see the effect on the system. The parameter is associated with a double-sided node such as a pump or valve. The user selects a parameter within the node input data, then defines an allowable range. The program will run multiple analyses simultaneously to output the variation in the remainder of system based on iterative values within the allowable range. For instance, vary the flow coefficient of a valve to see the effect on the system pressures and flows. This is a KYPipe-only feature, available within the KYnetic Interface and the KYnetic Ribbon Interface. More
Device & Element Libraries Users can create customized libraries for devices and elements. More
Users can create customized libraries for devices and elements. More
Elements & Devices Node elements & devices include junctions, tanks, reservoirs, pumps, regulating valves, loss elements, and loss elements defined by manufacturer data from a library. More
Node elements & devices include junctions, tanks, reservoirs, pumps, regulating valves, loss elements, and loss elements defined by manufacturer data from a library. More
Find Minimum/Maximum, Next Higher/Next Lower Pipe and Node Results This feature toggles sequentially between nodes with higher or lower values of Result-A, including buttons to immediately display the node or pipe with the highest or lowest value of Result-A. Result-A is a placeholder that can be set to display the following system variables: Nodes Pressure. Hydraulic Grade Line. Grade. Flow/Demand (Some Nodes Only). Volume (Some Nodes Only). Pipes Flow. Velocity. Headloss. Headloss per Thousand Map Units (Feet or Meters). Volume (Some Nodes Only).
Find Minimum/Maximum, Next Higher/Next Lower Pipe and Node Results
This feature toggles sequentially between nodes with higher or lower values of Result-A, including buttons to immediately display the node or pipe with the highest or lowest value of Result-A. Result-A is a placeholder that can be set to display the following system variables: Nodes Pressure. Hydraulic Grade Line. Grade. Flow/Demand (Some Nodes Only). Volume (Some Nodes Only). Pipes Flow. Velocity. Headloss. Headloss per Thousand Map Units (Feet or Meters). Volume (Some Nodes Only).
Flow/Demand (Some Nodes Only).
Headloss per Thousand Map Units (Feet or Meters).
Fittings Loss Coefficients Enter the number of each type of fitting from the extensive drop-down list and the loss coefficient Ks will be automatically summed for any pipe section.
Enter the number of each type of fitting from the extensive drop-down list and the loss coefficient Ks will be automatically summed for any pipe section.
Generate Change Pattern Generates a change pattern for a selected group of nodes in which each on/off combination is included (KYnetic only). More
Generates a change pattern for a selected group of nodes in which each on/off combination is included (KYnetic only). More
Google Earth Import & Export Imports and exports model files to and from Google Earth. More
Imports and exports model files to and from Google Earth. More
Google Maps & Google Elevations Retrieve Google Maps & Google Elevations data.
Google Maps & Google Elevations
Retrieve Google Maps & Google Elevations data.
Internet Elevation Retrieval & Background Maps Apply internet-based maps to both new and existing model backgrounds. Elevation data may be imported and applied to the nodes in the model. More
Internet Elevation Retrieval & Background Maps
Apply internet-based maps to both new and existing model backgrounds. Elevation data may be imported and applied to the nodes in the model. More
Interpolate Elevations Uses existing elevation data to update nodes with missing elevations. More
Uses existing elevation data to update nodes with missing elevations. More
Maximum Cavitation Volume for Nodes in Surge Maximum Cavitation Volume Now Available. Previously, Surge computed the cavitation volume at each node, but these data were not readily available to the user. New for Surge in 2024, the software now reports the Maximum Cavitation Volume for the entire analytical run. These data are available both as a Report (encompassing the maximum cavitation volume at all nodes throughout the simulation) as well as an individual result that can be seen within the Node Info Window (which reports the mazimum cavitation volume for the entire the simulation at that node only).
Maximum Cavitation Volume for Nodes in Surge
Maximum Cavitation Volume Now Available. Previously, Surge computed the cavitation volume at each node, but these data were not readily available to the user. New for Surge in 2024, the software now reports the Maximum Cavitation Volume for the entire analytical run. These data are available both as a Report (encompassing the maximum cavitation volume at all nodes throughout the simulation) as well as an individual result that can be seen within the Node Info Window (which reports the mazimum cavitation volume for the entire the simulation at that node only).
Operational Control Screen The Operational Control Screen is a unique and very useful tool for presentations and operational and design studies. There is no better tool for presenting the impact of changes on the operation of a distribution system. More
The Operational Control Screen is a unique and very useful tool for presentations and operational and design studies. There is no better tool for presenting the impact of changes on the operation of a distribution system. More
Pipe Break Tool Highlights pipes and the on/off or active valves affected by the break.
Highlights pipes and the on/off or active valves affected by the break.
Pipe Schedules Select the Pipe Type from one of many Pipe Schedules and the pipe data fields are automatically filled or create a customized schedule which may be reused in multiple models.
Select the Pipe Type from one of many Pipe Schedules and the pipe data fields are automatically filled or create a customized schedule which may be reused in multiple models.
Piping and Instrumentation Diagrams Create Piping and Instrumentation Diagrams (PIDs) of existing model files. More
Piping and Instrumentation Diagrams
Create Piping and Instrumentation Diagrams (PIDs) of existing model files. More
Plot Pump Curves Generates a plot of pump curves using head/flow data.
Generates a plot of pump curves using head/flow data.
Presentation Generator Create detailed PowerPoint, Word & HTML reports within the KYnetic interface. Add maps, images, videos, tables and graphs for dynamic presentations. More
Create detailed PowerPoint, Word & HTML reports within the KYnetic interface. Add maps, images, videos, tables and graphs for dynamic presentations. More
Printing, Images & PDFs Export maps, graphs, tables and reports directly to a PDF, JPG or BMP file without loss of quality. More
Export maps, graphs, tables and reports directly to a PDF, JPG or BMP file without loss of quality. More
Profile View The Profile View allows the system to be seen in a side view for any defined profile. System data and results are still accessible but editing is not allowed. Fast switching between the plan and profile view.
The Profile View allows the system to be seen in a side view for any defined profile. System data and results are still accessible but editing is not allowed. Fast switching between the plan and profile view.
Pump Cycles Hydrotank Tool Pumps in combination with Hydropneumatic Tanks (hydrotanks) are often used in piping systems with no storage capacity. The Pump Cycles tool helps to size and validate hydrotank/pump combinations based on different demand levels with a goal of idealizing the number of pump cycles required. This is a Premium Surge feature. More
Pumps in combination with Hydropneumatic Tanks (hydrotanks) are often used in piping systems with no storage capacity. The Pump Cycles tool helps to size and validate hydrotank/pump combinations based on different demand levels with a goal of idealizing the number of pump cycles required. This is a Premium Surge feature. More
QuickView Feature QuickView limits map features, making loading and editing large modeling files faster. When a large model file is detected during loading, the interface automatically prompts the user with an option to enable this feature. It is automatically turned off when making presentations, or when the Map Refresh button is clicked. QuickView can easily be turned on and off while editing a file.
QuickView limits map features, making loading and editing large modeling files faster. When a large model file is detected during loading, the interface automatically prompts the user with an option to enable this feature. It is automatically turned off when making presentations, or when the Map Refresh button is clicked. QuickView can easily be turned on and off while editing a file.
Series or Parallel Pump Curves Graph Create a combined pump curve in either series or parallel for any two pump IDs in the model. See also System Curves.
Series or Parallel Pump Curves Graph
Create a combined pump curve in either series or parallel for any two pump IDs in the model. See also System Curves.
Snap Hydrants, Valves, and Meters The Snap Hydrants, Valves, and Meters feature connects floating nodes to the nearest pipe. This is useful when adding hydrants, etc., from GIS data to an existing model. More
Snap Hydrants, Valves, and Meters
The Snap Hydrants, Valves, and Meters feature connects floating nodes to the nearest pipe. This is useful when adding hydrants, etc., from GIS data to an existing model. More
Steady-State Analysis (in Addition to Transient Analysis) Users can perform a steady-state analysis before beginning a transient analysis, verifying model validity. A steady-state analysis can also be used to generate a system curve.
Steady-State Analysis (in Addition to Transient Analysis)
Users can perform a steady-state analysis before beginning a transient analysis, verifying model validity. A steady-state analysis can also be used to generate a system curve.
Surge Pipe Break Analysis When utilizing this feature, the user clicks on a pipe, and the software simulates a break, performing a transient analysis at that location. The area of the pipe break can be determined by the user (from 0.0 to 1.0 times the cross-sectional area of the pipe). There is no need to set up and simulate the pipe break via the Node Changes Table.
When utilizing this feature, the user clicks on a pipe, and the software simulates a break, performing a transient analysis at that location. The area of the pipe break can be determined by the user (from 0.0 to 1.0 times the cross-sectional area of the pipe). There is no need to set up and simulate the pipe break via the Node Changes Table.
Surge Protection Devices Siphon breakers, dynamic air valves, pressure relief valves, surge anticipation valves, surge bladder tanks & electronically-actuated surge anticipation valves are just a few of the unique devices available. More
Siphon breakers, dynamic air valves, pressure relief valves, surge anticipation valves, surge bladder tanks & electronically-actuated surge anticipation valves are just a few of the unique devices available. More
System Curve Analysis The System Curve feature from KYPipe is now available in Surge. Users can plot the system curve against the pump curve of any pumps in the model, or in a pump library. Further, this feature can add curves based on multiple pumps in series or parallel. Users can also plot the System Curve against the current pumps in the model or library, designating Speed Ratios above or below 1.0
The System Curve feature from KYPipe is now available in Surge. Users can plot the system curve against the pump curve of any pumps in the model, or in a pump library. Further, this feature can add curves based on multiple pumps in series or parallel. Users can also plot the System Curve against the current pumps in the model or library, designating Speed Ratios above or below 1.0
Transient-Only Pressures Graph Transient Pressure Graph and Table. Formerly, Surge results were shown within graphs and tables as regular pressure results (i.e., the gauge pressure within the system). New for Pipe2024, this feature allows the user to plot/view only the transient-related pressures within graphs and tables – the steady-state pressures are mathematically removed from the curves/results so that graphs and tables only display the effects due to the transient-producing event(s). Thus, the pressure value on the graph starts at 0 psi instead of the steady-state gauge pressure within the system.
Transient-Only Pressures Graph
Transient Pressure Graph and Table. Formerly, Surge results were shown within graphs and tables as regular pressure results (i.e., the gauge pressure within the system). New for Pipe2024, this feature allows the user to plot/view only the transient-related pressures within graphs and tables – the steady-state pressures are mathematically removed from the curves/results so that graphs and tables only display the effects due to the transient-producing event(s). Thus, the pressure value on the graph starts at 0 psi instead of the steady-state gauge pressure within the system.
TranSurge TranSurge is used for transient modeling of long transmission mains. Available as a stand-alone license or a add-on to a Surge license. More
TranSurge is used for transient modeling of long transmission mains. Available as a stand-alone license or a add-on to a Surge license. More
Travel Distance Displays the travel distance from a selected node to all other nodes in the system (KYnetic only). More
Displays the travel distance from a selected node to all other nodes in the system (KYnetic only). More
Travel Time/Path Animation of the travel time from a selected end node to all reachable nodes in the system (KYnetic only). More
Animation of the travel time from a selected end node to all reachable nodes in the system (KYnetic only). More
Work Locally Sometimes issues occur when users run modeling files that are stored on external locations, including cloud locations, and shared or network drives. This feature is designed to allow users to seamlessly maintain project folders in these external locations. Upon opening a modeling file, this feature copies the file from the shared drive/remote folder to the local folder, and the user works from there until the file is closed. At this point, the modeling file is written to the shared drive. This is useful for users who are required to maintain a central store of files.
Sometimes issues occur when users run modeling files that are stored on external locations, including cloud locations, and shared or network drives. This feature is designed to allow users to seamlessly maintain project folders in these external locations. Upon opening a modeling file, this feature copies the file from the shared drive/remote folder to the local folder, and the user works from there until the file is closed. At this point, the modeling file is written to the shared drive. This is useful for users who are required to maintain a central store of files.
Up to 1000 Surge Protection Devices Allowed Surge Protection Device Limit Increased – (Surge only) the allowable number of SDOs, or surge protection devices of all kinds, has been increased from 600 to 1000.
Up to 1000 Surge Protection Devices Allowed
Surge Protection Device Limit Increased – (Surge only) the allowable number of SDOs, or surge protection devices of all kinds, has been increased from 600 to 1000.